Bando 6-3V475 Power Ace Combo ELECTRIC MOTORSBando 6 3V475 To resolve problem applications where belts are flipping over or jumping out of the sheaves, utilize Bandos series of Combo belts. The tie band assures lateral rigidity and guides the belts into the sheave grooves. The tie band, reinforced with high strength transverse tensile cords, is fully oil and heat resistant and permanently welds the individual belts together. Combos utilize the premium quality Power King and Power Ace belts, with
Amperage181
Bando - DC6X370 Duraflex® VC and DC are the most precise V-belts available
4 % Electrically Isolated Bearing Not Electrically Isolated Enclosure Modification 841 Feedback Device NO FEEDBACK High Voltage Full Load Amps 35
00 Hz Motor Letter Type Three Phase Phase 3 XP Class and Group None XP Division Not Applicable Agency Approvals CULUS WEEE Auxillary Box No Auxillary Box Auxillary Box Lead Termination None Base Indicator Rigid Bearing Grease Type Polyrex EM (-20F +300F) Blower None Constant Torque Speed Range 6 Design Code B Drip Cover No Drip Cover Electrically Isolated Bearing Not Electrically Isolated Feedback Device NO FEEDBACK Heater Indicator No Heater Inverter Code Inverter Duty IP Rating NONE Lifting Lugs No Lifting Lugs Locked Bearing Indicator Locked Bearing Motor Lead Termination Flying Leads Motor Lead Quantity/Wire Size 9 @ 18 AWG Motor Type 3514B Mounting Arrangement F1 Number of Poles 4 Overall Length 12
3 A Rated torque 1330 ft
Bando - 60-S3M-387 Unique modified curvilinear tooth form enables the STS belt to transmit greater loads than like-sized drives having the standard high torque tooth profile
9x(Code J) No load current 10
00 % Rated voltage 400 V Rated current 56
lb Locked rotor torque 280 % Breakdown torque 280 % Locked rotor time 25s (cold) 14s (hot) Moment of inertia (J) 118 sq
D XP Division Division I Agency Approvals CSA EEV UL Ambient Temperature 40 °C Auxillary Box No Auxillary Box Auxillary Box Lead Termination None Base Indicator Rigid Bearing Grease Type Polyrex EM (-20F +300F) Blower None Constant Torque Speed Range 6 Current @ Voltage 56
6 POLES 2 NUMBER SPEEDS 1 RPM 3570 HERTZ 60 VOLTS PRIMARY 460 VOLTS 460 FRME 405 SHAFT CODE TS MOUNTING HORZ-FOOTED ASSEMBLY POSITION F1 MOTOR TYPE CE OPPOSITE END BEARING 6316-J/C3 SHAFT END BEARING 6316-J/C3 AMBIENT 40 ROTATION DUAL SERVICE FACTOR 1
Bando - 150-S3M-432 Unique modified curvilinear tooth form enables the STS belt to transmit greater loads than like-sized drives having the standard high torque tooth profile